Create a Joomla website with Joomla Templates. These Joomla Themes are reviewed and tested for optimal performance. High Quality, Premium Joomla Templates for Your Site

ADSS MLT Câble fibre optique

Oxin All Dielectric Self-Supporting Multi Loose Tube (MLT) cables are constructed of fibers inside gel filled central loose tubes, wrapped around an FRP central strength member. This is encased in a PE inner jacket, aramid yarns and a PE outer jacket.

Features and Benefits:
  • Lightweight, all-dielectric construction is ideal for use near electrical power lines and in areas of frequent lightning strikes
  • Round construction is ideal for minimum wind drag and ice build-up
  • High tensile strength
  • Wide operating temperature range: -40°C ~ +70°C
Applications:
  • Suitable for installation on poles and on the power distribution network
Parameter Unit F8 F12 F16 F24
Span m 300 500 600 900
Outer Diameter mm 12.3 12.8 13.8 14.8
Weight PE Jacket kg/km 136.3 146.5 165.9 185.8
Cross Sectional Area mm2 117.90 128.19 150.21 171.65
Area Of Strength Member mm2 13.62 20.43 26.10 39.72
RTS kN 20.40 30.60 39.10 59.50
MOTS kN 8.16 12.24 15.64 23.80
EDS kN 5.10 7.65 9.78 14.88
Ultimate Exceptional Stress kN 12.24 18.36 23.46 35.70
Modulus kN/mm 15.27 20.11 21.71 28.07
Thermal Expansion Coefficient 10-6/°C 3.78 2.12 1.42 0.41
Crush Strength Operation N/10cm 1000 1000 1000 1000
Installation N/10cm 2200 2200 2200 2200
Safety Factor 2.5 2.5 2.5 2.5
Min. Bend Radius Operation mm 185 192 207 222
Installation mm 308 320 345 370
Temperature Installation °C -10~+60 -10~+60 -10~+60 -10~+60
Transport °C -40~+70 -40~+70 -40~+70 -40~+70
Operation °C -40~+70 -40~+70 -40~+70 -40~+70
Sag (5mm inc load average 20°C) PE Jacket % 1.06 1.47 1.57 1.78