Tight Buffered Distribution Câble
Oxin tight buffered and breakout cables are manufactured using 900µm buffered fibers in a variety of constructions. Aramid or e-glass yarns are utilized to provide strength and to protect the fibers. The cables can be supplied with either Low Smoke Zero Halogen or PVC jackets, depending on the application. Oxin tight buffered and breakout cables have a variety of applications. These include horizontal distribution, backbone and riser applications, patch cords, rack to rack links in equipment rooms and short run external inter-building links.
Features and Benefits:- Choice of fiber type
- Colour coded fibers
- High strength E-Glass rodent resistant yarn strength members for ease of handling
- LSZH jacket
- Easy to strip
- Internal cable for installation in trunking, under floor or ceiling spaces
- Fiber backbones in riser and horizontal configurations
Technical Characteristics | Parameter | unit | 4 core | 8 core | 12 core | 24 core |
Outer Diameter | mm | 4.8 ± 0.3 mm | 5.8 ± 0.3 mm | 6.8 ± 0.3 mm | 8.0 ± 0.3 mm | |
Weight | kg/km | 26 | 34 | 37 | 55 | |
Max. Load (installation) | N | 600 | 750 | 750 | 900 | |
Max. Load (installed) | N | 300 | 375 | 375 | 450 | |
Min. Bend Radius (installation) | mm | 96 | 116 | 130 | 150 | |
Min. Bend Radius (installed) | mm | 48 | 58 | 65 | 75 | |
Fire Performance | LSZH | LSZH | LSZH | LSZH | ||
Operating Temp. | °C | -20 ~ +60 | -20 ~ +60 | -20 ~ +60 | -20 ~ +60 | |
Storage Temp. | °C | -20 ~ +60 | -20 ~ +60 | -20 ~ +60 | -20 ~ +60 | |
Installation Temp. | °C | -20 ~ +60 | -20 ~ +60 | -20 ~ +60 | -20 ~ +60 | |
Crush Resistance | N/(100mm) | 1000 N/(100mm) | 1000 | 1000 | 1000 |