Bare Fiber PLC Splitter

Planar Lightwave Circuit (PLC) Splitter is a type of optical power management device that is fabricated using silica optical waveguide technology. It features small size, high reliability, wide operating wavelength range and good channel-to-channel uniformity, and is widely used in PON networks to realize optical signal power splitting. Oxin provides whole series of 1xN splitter and 2xN splitter products that are tailored for specific applications.

Features and Benefits:
  • Low Insertion loss
  • Low PDL
  • Compact Design
  • Good channel-to-channel uniformity
  • Wide Operating Wavelength: From 1260nm to 1650nm
  • Wide Operating Temperature: From -40°C to 85°C
  • High Reliability and Stability
Applications:
  • Can be used for FTTX Systems
  • Passive Optical Networks (PON)
  • CATV TV Networks (CATV)
  • Optical Signal Distribution
Certification and Compliance:
  • YD/T1117-2001
  • Telcordia GR-1221-CORE-1999
  • Telcordia GR-1209-CORE-2001
1xN PLC Splitter Specifications
Port Configuration 1x2 1x4 1x8 1x16 1x32 1x64
Fiber Type 250µm bare fiber
Operating Wavelength (nm) 1260 ~ 1650
Insertion Loss (dB) Typical 3.7 7.0 10.2 13.4 16.3 20.0
Max 4.0 7.4 10.7 13.9 17.2 21.5
Loss Uniformity(dB) Max 0.4 0.6 0.8 1.2 1.5 2.5
Return Loss (dB) Min 55 55 55 55 55 55
Polarization Dependent Loss(dB) Max 0.2 0.2 0.3 0.3 0.3 0.4
Directivity (dB) Min 55 55 55 55 55 55
Wavelength Dependent Loss(dB) Max 0.4 0.4 0.4 0.5 0.5 0.5
Temperature Stability (-40~85 °C)(dB) Max 0.5 0.5 0.5 0.8 0.8 1.0
Operating Temperature (°C) -40 ~ 85
Storage Temperature (°C) -40 ~ 85
Package Size (mm) 40x4x4 50x7x4 60x12x4
Note: All the data above does not include connectors. Add an additional 0.2dB loss per connector.   2xN PLC Splitter Specifications
Port Configuration 2x2 2x4 2x8 2x16 2x32 2x64
Fiber Type 250µm bare fiber
Operating Wavelength (nm) 1260~1650
Insertion Loss (dB) Typical 3.8 7.2 10.6 14.4 17.4 21.0
Max 4.2 7.6 11.0 14.8 17.9 21.5
Loss Uniformity(dB) Max 1.0 1.2 1.5 1.8 2.0 2.0
Return Loss (dB) Min 55 55 55 55 55 55
Polarization Dependent Loss(dB) Max 0.2 0.2 0.3 0.4 0.4 0.4
Directivity (dB) Min 55 55 55 55 55 55
Wavelength Dependent Loss(dB) Max 0.4 0.4 0.4 0.5 0.5 0.5
Temperature Stability (-40~85 °C)(dB) Max 0.5 0.5 0.5 0.8 0.8 1.0
Operating Temperature (°C) -40~85
Storage Temperature (°C) -40~85
Package Size (mm) 50x4x4 60x7x4
Note: All the data above does not include connectors. Add an additional 0.2dB loss per connector.